EVALUATION OF METHODS IN DETECTING VANCOMYCIN MIC AMONG MRSA ISOLATES AND THE CHANGES IN ACCURACY RELATED TO DIFFERENT MIC VALUES

Authors

  • Fernanda Cristina Possamai Rossatto Federal University of Health Science of Porto Alegre; Department of Microbiology
  • Letícia Auler Proença Federal University of Health Science of Porto Alegre; Department of Microbiology
  • Ana Paula Becker Mãe de Deus Hospital; Department of Microbiology
  • Alessandro Conrado de Oliveira Silveira Federal University of Health Science of Porto Alegre; Department of Microbiology
  • Juliana Caierão Federal University of Health Science of Porto Alegre; Department of Microbiology
  • Pedro Alves D'azevedo Federal University of Health Science of Porto Alegre; Department of Microbiology

Abstract

INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.

Downloads

Download data is not yet available.

Downloads

Published

2014-12-01

Issue

Section

Microbiology

How to Cite

Rossatto, F. C. P., Proença, L. A., Becker, A. P., Silveira, A. C. de O., Caierão, J., & D'azevedo, P. A. (2014). EVALUATION OF METHODS IN DETECTING VANCOMYCIN MIC AMONG MRSA ISOLATES AND THE CHANGES IN ACCURACY RELATED TO DIFFERENT MIC VALUES. Revista Do Instituto De Medicina Tropical De São Paulo, 56(6), 469-472. https://revistas.usp.br/rimtsp/article/view/87656