Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)

Autores

  • Amanda de Freitas Ferreira Federal University of Uberlândia; Dental School
  • João César Guimarães Henriques Federal University of Uberlândia; Dental School
  • Guilherme Araújo Almeida Federal University of Uberlândia; Dental School
  • Asbel Rodrigues Machado Federal University of Alfenas; Dental School
  • Naila Aparecida de Godoi Machado Federal University of Uberlândia; Dental School
  • Alfredo Júlio Fernandes Neto Federal University of Uberlândia; Dental School

DOI:

https://doi.org/10.1590/S1678-77572009000700006

Palavras-chave:

Computed tomography, Centric relation, Occlusion

Resumo

This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consisted of 10 asymptomatic young adult patients divided into two types of standard occlusion: normal occlusion and Angle Class I occlusion. In order to obtain the centric relation, a JIG device and mandible manipulation were used to deprogram the habitual conditions of the jaw. The evaluations were conducted in both frontal and lateral tomographic images, showing the condyle/articular fossa relation. The images were processed in the software included in the NewTom 3G device (QR NNT software version 2.00), and 8 tomographic images were obtained per patient, four laterally and four frontally exhibiting the TMA's (in CR and MI, on both sides, right and left). By means of tools included in another software, linear and angular measurements were performed and statistically analyzed by student t test. According to the methodology and the analysis performed in asymptomatic patients, it was not possible to detect statistically significant differences between the positions of centric relation and maximum intercuspation. However, the resources of cone beam tomography are of extreme relevance to the completion of further studies that use heterogeneous groups of samples in order to compare the results.

Downloads

Os dados de download ainda não estão disponíveis.

Downloads

Publicado

2009-01-01

Edição

Seção

nd

Como Citar

Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM) . (2009). Journal of Applied Oral Science, 17(spe), 27-34. https://doi.org/10.1590/S1678-77572009000700006