Bond strength and morphology of enamel using self-etching adhesive systems with different acidities

Authors

  • Sandra Kiss Moura University North of Paraná; Department of Dentistry
  • Alessandra Reis State University of Ponta Grossa; Department of Operative Dentistry and Dental Materials
  • Arlete Pelizzaro University of Western Santa Catarina; Department of Operative Dentistry and Dental Materials
  • Karen Dal-Bianco University of Western Santa Catarina; Department of Operative Dentistry and Dental Materials
  • Alessandro Dourado Loguercio State University of Ponta Grossa; Department of Operative Dentistry and Dental Materials
  • Victor Elias Arana-Chavez University of São Paulo; Department of Dental Materials
  • Rosa Helena Miranda Grande University of São Paulo; Department of Dental Materials

DOI:

https://doi.org/10.1590/S1678-77572009000400009

Keywords:

Enamel, Bonding, Adhesive systems, Morphology

Abstract

OBJECTIVES: To assess the bond strength and the morphology of enamel after application of self-etching adhesive systems with different acidities. The tested hypothesis was that the performance of the self-etching adhesive systems does not vary for the studied parameters. MATERIAL AND METHODS: Composite resin (Filtek Z250) buildups were bonded to untreated (prophylaxis) and treated (bur-cut or SiC-paper) enamel surfaces of third molars after application of four self-etching and two etch-and-rinse adhesive systems (n=6/condition): Clearfil SE Bond (CSE); OptiBond Solo Plus Self-Etch (OP); AdheSe (AD); Tyrian Self Priming Etching (TY), Adper Scotchbond Multi-Purpose Plus (SBMP) and Adper Single Bond (SB). After storage in water (24 h/37°C), the bonded specimens were sectioned into sticks with 0.8 mm² cross-sectional area and the microtensile bond strength was tested at a crosshead speed of 0.5 mm/min. The mean bond strength values (MPa) were subjected to two-way ANOVA and Tukey's test (α=0.05). The etching patterns of the adhesive systems were also observed with a scanning electron microscope. RESULTS: The main factor adhesive system was statistically significant (p<0.05). The mean bond strength values (MPa) and standard deviations were: CSE (20.5±3.5), OP (11.3±2.3), AD (11.2±2.8), TY (11.1±3.0), SBMP (21.9±4.0) and SB (24.9±3.0). Different etching patterns were observed for the self-etching primers depending on the enamel treatment and the pH of the adhesive system. CONCLUSION: Although there is a tendency towards using adhesive systems with simplified application procedures, this may compromise the bonding performance of some systems to enamel, even when the prismless enamel is removed.

Downloads

Download data is not yet available.

Downloads

Published

2009-08-01

Issue

Section

Original Articles

How to Cite

Bond strength and morphology of enamel using self-etching adhesive systems with different acidities . (2009). Journal of Applied Oral Science, 17(4), 315-325. https://doi.org/10.1590/S1678-77572009000400009