Effect of the number of abutments on biomechanics of Branemark prosthesis with straight and tilted distal implants

Authors

  • Marcos Michelon Naconecy Pontifical Catholic University of Rio Grande do Sul; Graduate Program in Dentistry
  • Tomás Geremia Pontifical Catholic University of Rio Grande do Sul; Department of Prosthodontics
  • André Cervieri Lutheran University of Brazil; Department of Engineering
  • Eduardo Rolim Teixeira Pontifical Catholic University of Rio Grande do Sul; Department of Prosthodontics
  • Rosemary Sadami Shinkai Pontifical Catholic University of Rio Grande do Sul; Department of Prosthodontics

DOI:

https://doi.org/10.1590/S1678-77572010000200013

Keywords:

Biomechanics, Implant-supported prostheses, Number of abutments, Tilted implants, Strain gauges

Abstract

OBJECTIVE: This study aimed to evaluate the bending moments, and compressive and tensile forces in implant-supported prostheses with three, four or five abutments. MATERIAL AND METHODS: Ten Pd-Ag frameworks were tested over two master models with: 1) parallel vertical implants, and 2) tilted distal implants. Strain gauges were fixed on the abutments of each master model to measure the deformation when a static load of 50 N was applied on the cantilever (15 mm). The deformation values were measured when the metallic frameworks were tested over three, four or five abutments, and transformed into force and bending moment values. Data were analyzed by ANOVA and Tukey's test for multiple comparisons at 5% level of significance. RESULTS: Abutment #1 (adjacent to the cantilever) had the highest values of force and sagittal bending moment for all tests with three, four or five abutments. Independently from the number of abutments, axial force in abutment #1 was higher in the vertical model than in the tilted model. Total moment was higher with three abutments than with four or five abutments. Independently from the inclination of implants, the mean force with four or five abutments was lower than that with three abutments. CONCLUSION: The results suggest that in the set-ups with four or five abutments tilted distal implants reduced axial force and did not increase bending moments.

Downloads

Download data is not yet available.

Downloads

Published

2010-04-01

Issue

Section

Original Articles

How to Cite

Effect of the number of abutments on biomechanics of Branemark prosthesis with straight and tilted distal implants . (2010). Journal of Applied Oral Science, 18(2), 178-185. https://doi.org/10.1590/S1678-77572010000200013